      KLD-FAE Series

      Automatic Electrical Fire-extinguishing System

      A new generation of wireless automatic electrical fire extinguishing system integrates "early warning, alarm and fire extinguishing", which is widely applied to power distribution cabinets in multiple scenarios.

      PRODUCT OVERVIEW

      In the power distribution system, most of the equipment are power distribution cabinets, network cabinets, cables and wires in cable tunnels or bridges. Due to the relatively closed space, the traditional fire alarm system focuses on the protection of the entire computer room or power distribution room. The fire can not be detected through video surveillance in the early stage, and the fire-extinguisng system will only started when the fire spreaded to a certain extent, but the equipment has already experienced serious damage. And there is no way to implement real-time monitoring and automatic fire extinguishing of confined spaces, thus can not control the source of the fire!

      KLD-FAE series automatic electrical fire-extinguishing system integrates "early warning, alarm, extinguishing" functions, which has superior performance and high reliability, and it’s easy to install and maintain, meeting the urgent need of all users. It can be used independently or be networked with the control center.
      The system rapidly monitors the changes in the surrounding environment through the installation of distributed remote sensing module. Once the fire is detected, the system will quickly send an alarm signal through wireless communication to inform the location and the time of occurrence of the fire. It can automatically extinguish the fire while remotely informing the fire situation to ensure that the fire can be extinguished the first time.

      AUTOMATIC ELECTRICAL
      FIRE-EXTINGUISHING SYSTEM

      KLD-FAE series automatic electrical fire-extinguishing system is mainly composed of three main devices: automatic alarm and fire-extinguishing system host, automatic alarm and fire-extinguishing controller and automatic fire-extinguishing device. The host receives the online monitoring data from the automatic alarm and fire-extinguishing controller and displays the temperature and smoke detection status in real time through wireless transmission. When an electrical fire occurs, the controller can quickly control the automatic fire-extinguishing device to extinguish the fire.

      SMS ALARM FUNCTION

      The system configuration is flexible and convenient, and can be installed anywhere in the monitored cabinet that needs to extinguish the fire, It protects the system uninterruptedly in 24-hours and the User can remotely receive the early warning alarm SMS information.

      SMS ALARM FUNCTION

      The system configuration is flexible and convenient, and can be installed anywhere in the monitored cabinet that needs to extinguish the fire, It protects the system uninterruptedly in 24-hours and the User can remotely receive the early warning alarm SMS information.

      COMPREHENSIVE PROTECTION FUNCTION

      KLD-FAE series automatic electrical fire-extinguishing system is a complete electrical fire monitoring and control system that has the performance of abnormal warning, fire alarm, automatic fire extinguishing, system process display and fire protection record management.

      SINGLE SERIES AUTOMATIC
      FIRE-EXTINGUISHING EQUIPMENT

      Single series automatic fire-extinguishing equipment has the ability to operate independently and does not depend on external equipment or system support, which not only simplifies the installation process, but also reduces the maintenance and management costs.

      MATCHBOX SERIES AUTOMATIC
      FIRE-EXTINGUISHING EQUIPMENT

      Matchbox series follows a miniaturized design concept that aims to provide quick and efficient fire extinguishing, which can quickly respond to fire and automaticaly extinguish the fire. The products can easily be placed in narrow spaces such as communication cabinets, small power distribution boxes, drawers, etc., saving a lot of valuable spaces for users.

      Technical Parameters

      Automatic alarm and fire extinguishing system host KLD-FAE-MC
      InputPower DC 12V(Adaptable to power AC220V input, DC12V output)
      Operating frequency 50Hz/60Hz±5Hz
      Communication RS232 or RS485, GSM(optional)
      Wireless communication band Dual frequency GSM900MHz and DCS1800 MHz(Phase 2+)
      Alarm mode 8 alarm phone numbers configurable
      Display LCD touch display panel
      Ambient temperature -40℃~+85℃
      EnvironmentHumidity Maximum 95%RH (no condensing)
      Altitude ≤2000 meters (higher altitude can be customized)
      Protection degree IP20(other requirements can be customized)
      Automatic alarm fire-extinguishing controller KLD-FAE-CT
      InputPower DC 12V
      Operating frequency 50Hz/60Hz±5Hz
      Detection accuracy ±0.5℃
      Smoke sensitivity Compiles with UL-217 standard
      Alarm mode Audible and visual alarm (optional)
      Alarm intensity 85dB(10ft)
      Ambient temperature -40℃~+125℃
      EnvironmentHumidity Maximum 95%RH (no condensing)
      Altitude ≤2000 meters (higher altitude can be customized)
      Protection degree IP20(other requirements can be customized)
      Automatic fire extinguishing equippment KLD-FAE-ED
      Operating voltage DC12V
      Starting current 0.3A-1A
      Protection space ≤3m3(others can be customized)
      Release time ≤30s
      Spray surface temperature ≤200℃
      Thermal clearance 100mm at the nozzle≤75℃
      Product insulation performance ≥20MΩ
      Service life 10 years
      Connection mode Multiple pcs in series
      Ambient temperature -40℃~+125℃
      EnvironmentHumidity Maximum 95%RH (no condensing)
      Altitude ≤2000 meters (higher altitude can be customized)
      Protection degree IP20(other requirements can be customized)

      S SeriesAutomatic fire extinguishing equippment KLD-FAE-ED1S
      Protection space ≤3m3(others can be customized)
      Release time ≤30s
      Spray surface temperature ≤200℃
      Thermal clearance 100mm at the nozzle≤75℃
      Product insulation performance ≥20MΩ
      Service life 10 years
      Ambient temperature -40℃~+125℃
      EnvironmentHumidity Maximum 95%RH (no condensing)
      Altitude <1500 meters (higher altitude can be customized)
      Protection degree IP20(other requirements can be customized)
      Starting mode Thermal sensitive wire

      Technical Parameters


      Automatic Electrical Fire-extinguishing System

      • InputPower :DC 12V(Adaptable to power AC220V input, DC12V output)

        Operating frequency:50Hz/60Hz±5Hz

        Communication:RS232 or RS485, GSM(optional)

        Wireless communication band:Dual frequency GSM900MHz and DCS1800 MHz(Phase 2+)

        Alarm mode:8 alarm phone numbers configurable

        Display:LCD touch display panel

        Ambient temperature:-40℃~+85℃

        EnvironmentHumidity:Maximum 95%RH (no condensing)

        Altitude:≤2000 meters (higher altitude can be customized)

        Protection degree:IP20(other requirements can be customized)

      Automatic alarm fire-extinguishing controller

      • InputPower :DC 12V

        Operating frequency:50Hz/60Hz±5Hz

        Detection accuracy:±0.5℃

        Smoke sensitivity:Compiles with UL-217 standard

        Alarm mode:Audible and visual alarm (optional)

        Alarm intensity:85dB(10ft)

        Ambient temperature:-40℃~+125℃

        EnvironmentHumidity:Maximum 95%RH (no condensing)

        Altitude:≤2000 meters (higher altitude can be customized)

        Protection degree:IP20(other requirements can be customized)

      Automatic fire extinguishing equippment

      • Operating voltage:DC12V

        Starting current:0.3A-1A

        Protection space:≤3m3(others can be customized)

        Release time:≤30s

        Spray surface temperature:≤200℃

        Thermal clearance:100mm at the nozzle≤75℃

        Product insulation performance: ≥20MΩ

        Service life:10 years

        Connection mode:Multiple pcs in series

        Ambient temperature:-40℃~+125℃

        EnvironmentHumidity:Maximum 95%RH (no condensing)

        Altitude:≤2000 meters (higher altitude can be customized)

        Protection degree:IP20(other requirements can be customized)

      Series Automatic fire extinguishing equippment

      • Protection space:≤3m3(others can be customized)

        Release time:≤30s

        Spray surface temperature:≤200℃

        Thermal clearance:100mm at the nozzle≤75℃

        Product insulation performance: ≥20MΩ

        Service life:10 years

        Ambient temperature:-40℃~+125℃

        EnvironmentHumidity:Maximum 95%RH (no condensing)

        Altitude:<1500 meters (higher altitude can be customized)

        Protection degree:IP20(other requirements can be customized)

        Starting mode:Thermal sensitive wire

      page top
      主站蜘蛛池模板: 一本大道香蕉中文日本不卡高清二区 | 欧美精品1卡二卡三卡四卡| 亚洲国产精品综合久久20| 99精品热在线在线观看视| 《特殊的精油按摩》3| 亚洲国产欧美另类va在线观看| 欧美xxxx性bbbbb喷水| 国产无遮挡又黄又爽不要vip软件| 国产精品黄在线观看免费| 国产偷窥厕所一区二区| 国产一码二码三码区别| 18禁成人黄网站免费观看久久| 日韩在线一区二区不卡视频| 国产精品伊人久久综合网| 99精品国产综合久久久久五月天| 精品熟女亚洲av在线观看| 日韩中文字幕免费在线观看| 国精产品一二三区精华液| 日韩午夜在线视频观看| 一色桃子中出欲求不满人妻| 精品午夜福利短视频一区| 一本一道av中文字幕无码| 天堂亚洲免费视频| 中文字幕乱码一区二区免费| 性欧洲大肥性欧洲大肥女| 蜜桃伦理一区二区三区| 强开小雪的嫩苞又嫩又紧| 国产成人麻豆亚洲综合无码精品| 日韩中文字幕国产精品| 欧美人妻在线一区二区| 亚洲女人天堂| 精品无码国产自产拍在线观看| 狠狠色丁香婷婷综合| 国产区二区三区在线观看| 国产真人做受视频在线观看| 国产亚洲精品久久久久久久软件| 最新中文字幕av无码专区不| 国产激情第一区二区三区| 亚洲AV无码午夜嘿嘿嘿| 人妻少妇偷人精品一区| 免费区欧美一级猛片|