      ZN139-12 Series

      High-Voltage Vacuum

      Circuit Breaker

      (630-4000A)

      Concise Efficient Safe Comprehensive

      PRODUCT OVERVIEW

      High-voltage circuit breakers are very critical equipment in the power system, mainly used for controlling and protecting the power grid. They are capable of withstanding voltage levels up to kV, thus playing a vital role in the transmission and distribution process. They are suitable for controlling and protecting the grid with AC 50Hz, rated voltage of 12kV, and rated operating current of 630A to 4000A. It's widely used in used in industrial and mining enterprises, substations and other places, especially suitable for frequent operation.

      Product characteristics

      Enhance customer productivity

      Ensure safety of personnel and assets

      Optimize investment costs of whole life cycle

      Embedded pole

      ZN139 series vacuum circuit breaker adopts advanced casting embedded pole, and its special structure ensures that the vacuum arc-extinguishing chamber is reliably protected from mechanical impact, dust and moisture.

      Making and breaking current in vacuum
      • Vacuum circuit breakers do not require an arc-extinguishing and insulating medium. In fact, there are no substances in the chamber that can be ionized.
      • In any case, when the contacts are separated, the arc channel between the contacts is only made of the metallic vapors of the contact material.
      • When the main circuit current naturally disappears at zero crossing, the arc cannot be held. At the time, the rapidly decreasing carrier density and the rapidly condensing vacuum metal vapor quickly recover the insulation between the contacts.
      • Thus, the vacuum arc-extinguishing chamber recovers insulation and restores the capability to withstand the transient recovery voltage of the system, and eventually extinguishes the arc.

      Vacuum arc-extinguishing chamber

      The cup-shaped longitudinal magnetic contatcs are made of high-quality material and have low chopping current value; use the one-time tube sealing and exhausting technique, with high dielectric recovery strength and low air leakage rate; high mechanical strength, long mechanical life; strong making and breaking insulation recovery greatly reduces the reignition and TRV breakdown.

      Product structure

      Structural characteristics

      •  Extractable or fixed installation
      •  Solid, reliable, compact for less maintenance workload
      •  Mechanical anti-trip device as standard configuration
      •  Built-in energy storage rod for operating mechanism
      •  Pouring technology for lifetime embedded pole
      •  Vacuum making and breaking technology
      •  Vacuum arc-extinguishing chamber is reliably protected against mechanical impacts, dust and moisture
      •  A complete series of secondary accessories available
      •  Circuit breakers can be swung in and out manually, only when the cabinet door is closed
      •  位Safety interlock on the operating mechanism and the chassis prevents errors and dangerous operation
      •  Opening and closing buttons can be equipped with padlock or protective cover
      •  Suitable for different climates
      Technical parameters

      ZN139-12/D Permanent magnetic vacuum circuit breaker technical

      No. Name Unit Parameters
      1 Rated voltage kV 12
      2 Rated frequency withstand voltage phase-to-phase, phase-to-ground/contatcs (1min) kV 42/48
      3 Rated lightning impulse voltage phase-to-phase, phase-to-ground/contatcs (peak) kV 75/85
      4 Rated frequency Hz 50
      5 Rated current A 630-2500 630-3150* 630-4000*
      6 Rated short-circuit breaking current kA 20   25 31.5 40
      7 Rated short-circuit making current kA 50   63 80 100
      8 Rated peak withstand current kA 50   63 80 100
      9 Rated thermal stability current (RMS) kA 20   25 31.5 40
      10 Rated short-circuit duration s 4
      11 Times of rated short-circuit breaking current Times 30000/40000
      12 Mechanical life 30 30 30
      13 Rated current breaking times (electrical life) 30000/40000
      14 Mechanical life of permanent magnet mechanism - 120000 120000 120000
      15 Rated current breaking times (electrical life) A 630/400(40kA為800/400)
      16 Mechanical life of permanent magnet mechanism mm 150 210 275
      17 Rated single/back-to-back capacitor bank breaking current mm 9±1
      18 Phase spacing mm 3±1
      19 Clearance between open contacts(1) mm 3
      20 Contact overtravel ms ≤2

      Note: *3150A and above require forced air-cooling

      ZN139-12/G Permanent magnetic vacuum Circuit BreakerTechnical Parameters

      No. Name Unit Parameters
      1 Rated voltage kV 12
      2 Rated frequency withstand voltage phase-to-phase, phase-to-ground/contatcs (1min) kV 42/48
      3 Rated lightning impulse voltage phase-to-phase, phase-to-ground/contatcs (peak) kV 75/85
      4 Rated frequency Hz 50
      5 Rated current A 630-2500 630-3150* 630-4000*
      6 Rated short-circuit breaking current kA 20   25 31.5 40
      7 Rated short-circuit making current kA 50   63 80 100
      8 Rated peak withstand current kA 50   63 80 100
      9 Rated thermal stability current (RMS) kA 20   25 31.5 40
      10 Rated short-circuit duration s 4
      11 Times of rated short-circuit breaking current Times 30 30 30
      12 Mechanical life Times 30000
      13 Rated current breaking times (electrical life) A 630/400(40kA為800/400)
      14 Mechanical life of permanent magnet mechanism mm 150 210 275
      15 Rated single/back-to-back capacitor bank breaking current mm 10±1
      16 Phase spacing mm 3±1
      17 Clearance between open contacts(1) mm 3
      18 Contact overtravel mm ≤2
      19 Allowable wear cumulative thickness of dynamic and static contacts ms ≤50
      20 Three-phase opening and closing non-synchronism ms ≤70
      21 Rated operating sequence - 0.3s?   180s          180s?   180s
      O —— CO—— CO          O —— CO—— CO

      Note: *3150A and above require forced air-cooling

      Selection table

      ZN139-12 Series High-voltage Vacuum Circuit Breaker

      ZN139 12 GD 630 25 Handcart type P H Anti-trip relay
      Product code Voltage level Product function Rated current Breaking current Installation method Mechanical life of permanent magnet mechanism(P) Pole spacing (H) Accessories
      ZN139:
      Vacuum Circuit Breaker
      12kV G: Spring embedded insulation
      GD: Permanent magnet embedded insulation
      D: Permanent magnet composite insulation
      T: Spring composite insulation
      630A
      1250A
      1600A
      2000A
      2500A
      3150A
      4000A
      20kA
      25kA
      31.5kA
      40kA
      Handcart type
      Fixed front mounted
      Fixed side mounted
      150mm
      210mm
      275mm
      275mm
      310mm
      Anti-trip relay
      Cut-off capacitor bank
      Undervoltage tripping device
      Door interlock
      Chassis extended swing handle/85mm
      Electric chassis + controller
      Chassis program lockProgram lock

      Technical Parameters


      • 1. Rated voltage(kV):12

        2. Rated frequency withstand voltage phase-to-phase, phase-to-ground/contatcs (1min)(kV):42/48

        3. Rated lightning impulse voltage phase-to-phase, phase-to-ground/contatcs (peak)(kV):75/85

        4. Rated frequency(Hz):50

        5. Rated current(A):630-2500/630-3150*/630-4000*

        6. Rated short-circuit breaking current(kA):20   25/31.5/40

        7. Rated short-circuit making current(kA):50  63/80/100

        8. Rated peak withstand current(kA):50  63/80/100

        9. Rated thermal stability current (RMS)(kA):20  25/31.5/40

        10. Rated short-circuit duration(s):4

        11. Times of rated short-circuit breaking current(Times):30/30/30

        12. Mechanical life(Times):30000/40000

        13. Rated current breaking times (electrical life):30000/40000

        14. Mechanical life of permanent magnet mechanism:120000/120000/120000

        15. Rated current breaking times (electrical life)(A):630/400(40kA為800/400)

        16. Mechanical life of permanent magnet mechanism(mm):150  210  275

        17. Rated single/back-to-back capacitor bank breaking current(mm):9±1

        18. Phase spacing(mm):3±1

        19. Clearance between open contacts(1)(mm):3

        20. Contact overtravel(ms):≤2

      • 1. Rated voltage(kV):12

        2. Rated frequency withstand voltage phase-to-phase, phase-to-ground/contatcs (1min)(kV):42/48

        3. Rated lightning impulse voltage phase-to-phase, phase-to-ground/contatcs (peak)(kV):75/85

        4. Rated frequency(Hz):50

        5. Rated current(A):630-2500/630-3150*/630-4000*

        6. Rated short-circuit breaking current(kA):20   25/31.5/40

        7. Rated short-circuit making current(kA):50  63/80/100

        8. Rated peak withstand current(kA):50  63/80/100

        9. Rated thermal stability current (RMS)(kA):20  25/31.5/40

        10. Rated short-circuit duration(s):4

        11. Times of rated short-circuit breaking current(Times):30/30/30

        12. Mechanical life(Times):30000

        13. Rated current breaking times (electrical life):630/400(40kA為800/400)

        14. Mechanical life of permanent magnet mechanism(mm):150  210  275

        15. Rated single/back-to-back capacitor bank breaking current(mm):10±1

        16. Phase spacing(mm):3±1

        17. Clearance between open contacts(1)(mm):3

        18. Contact overtravel(mm):≤2

        19. Allowable wear cumulative thickness of dynamic and static contacts(ms):≤50

        20. Three-phase opening and closing non-synchronism(ms):≤70

        21. Rated operating sequence:0.3s?180s O —— CO—— CO / 180s??180s O —— CO—— CO

      Selection table


      • Product code:ZN139:Vacuum Circuit Breaker

        Voltage level:12kV

        Product function:GG: Spring embedded insulation /GD: Permanent magnet embedded insulation /D: Permanent magnet composite insulation /T: Spring composite insulation

        Rated current:630A/1250A/1600A/2000A/2500A/3150A /4000A

        Breaking current:20kA/25kA/31.5kA/40kA

        Installation method:Handcart type/Fixed front mounted/Fixed side mounted

        Mechanical life of permanent magnet mechanism(P):150mm/210mm/275mm

        Pole spacing (H) :275mm/310mm

        Accessories:Anti-trip relay /Cut-off capacitor bank /Undervoltage tripping device /Door interlock /Chassis extended swing handle/85mm/Electric chassis + controller/Chassis program lockProgram lock

      page top
      主站蜘蛛池模板: 国产精品伦人视频免费看| 国产网友愉拍精品视频手机| 亚洲区日韩精品中文字幕| 91精品91久久久久久| gogogo电影在线观看免费| 在线高清理伦片a| 成人精品一区二区三区四| 好爽毛片一区二区三区四| 97夜夜澡人人双人人人喊| 青青草最新在线视频播放| 一区二区三区四区精品黄| 国产丰满乱子伦无码专区| 在线精品亚洲一区二区绿巨人| 国产AV一区二区精品凹凸| 久久精品人妻无码一区二区三| 爆乳日韩尤物无码一区| 国产高清小视频一区二区| 日韩有码中文字幕av| 麻豆麻豆麻豆麻豆麻豆麻豆| 欧美日韩一区二区综合| 福利视频一区二区在线| 少妇无码吹潮| 久久se精品一区精品二区国产| 激情综合色综合啪啪开心| 国产精品一区二区三区日韩| 少妇中文字幕乱码亚洲影视| 日本国产精品第一页久久| 亚洲伊人久久精品影院| 亚洲乱码中文字幕小综合| 中文字幕在线日韩| 中文字幕精品久久久久人妻红杏1| 伊人久久大香线蕉av网禁呦| 丰满少妇内射一区| 又爽又黄又无遮挡的激情视频| 国产精品久久久久久久9999| 亚洲人午夜精品射精日韩| 99久久国产综合精品女图图等你| 青青青草国产熟女大香蕉| 国产成人精品一区二区三区| av深夜免费在线观看| 久久一日本综合色鬼综合色|